114-10028
|
RayBiotech, Inc.
|
Guinea Pig anti-Mu Opioid receptor
|
Human
|
Immunocytochemistry 1:50-500, Immunohistochemistry 1:50-500
|
|
DS-MB-02356
|
RayBiotech, Inc.
|
Mouse anti-Human Synaptophysin
|
Human, This product reacts with pig, hamster and rat synaptophysin
|
ELISA (dilution: , 1/500), Immunohistology - Paraffin, Western Blotting
|
|
RB-01-0001-100
|
RayBiotech, Inc.
|
Mouse anti-Human bFGF/FGF basic/FGF2
|
|
ELISA: By direct ELISA, at least 1:10,000 dilution will yield positive signal using HRP conjugated rabbit anti-mouse Ig (Jackson Laboratories). It also can be used as capture purpose. Western Blot: Approx 17 kDa band was observed in recombinant protein and cell lysates(A431,Human colon carcinoma tissue or COLO 320DM). Its working dilution is used at 1:500-1000 as recommended. see picture below. (see image)Immunodetection Analysis: Representative blot from a previous lot. Lane 1.protein marker, Lane 2-3.recombinant protein(10-1ug/lane), Lane 3-4.Normal whole cell lysate as control. The membrane blot was probed with anti-bFGF primary antibody(1 �g/ml). Proteins were visualized using a goat anti-rabbit secondary antibody conjugated to HRP and chemiluminescence detection system. Other applications are not tested yet. Optimal dilutions should be determined by each laboratory for each application.
|
|
RB-08-0002-100
|
RayBiotech, Inc.
|
Rabbit anti-Human Vaspin
|
|
Direct and indirect ELISA: antibody detection limit dilution at least 1:1,000-2,000. Western Blot: Reacted with the approx 48-kDa Vaspin His tagged protein. Suggested blocking and dilution buffer is PBST with 0.05% Tween 20 with 5% skim milk. Suggested incubation time is 1 hour at room temperature. Recommended for use at dilution 1:500-1,000.
|
|
RB-01-0001B-50
|
RayBiotech, Inc.
|
Mouse anti-bFGF/FGF basic/FGF2 [+Biotin], Mouse Monoclonal Antibody
|
|
ELISA: By direct ELISA, at least 1:10,000 dilution will yield positive signal using HRP conjugated rabbit anti-mouse Ig (Jackson Laboratories). It also can be used as capture purpose. Western Blot: Approx 17 kDa band was observed in recombinant protein and cell lysates(A431,Human colon carcinoma tissue or COLO 320DM). Its working dilution is used at 1:500-1000 as recommended. see picture below. (see image)Immunodetection Analysis: Representative blot from a previous lot. Lane 1.protein marker, Lane 2-3.recombinant protein(10-1ug/lane), Lane 3-4.Normal whole cell lysate as control. The membrane blot was probed with anti-bFGF primary antibody(1 �g/ml). Proteins were visualized using a goat anti-rabbit secondary antibody conjugated to HRP and chemiluminescence detection system. Other applications are not tested yet. Optimal dilutions should be determined by each laboratory for each application.
|
|
128-10173-1
|
RayBiotech, Inc.
|
Vimentin [+Biotin], Mouse Monoclonal Antibody
|
|
Immunohistochemistry.<div class='ty-product-feature'><div class='ty-product-feature__label'>Cross Reactivity<div class='ty-product-feature__value'>Vimentin antibody will recognize most mammalian Vimentin except mouse and rat.
|
|
RB-08-0002B-50
|
RayBiotech, Inc.
|
Vaspin [+Biotin], Rabbit Polyclonal Antibody
|
|
Direct and indirect ELISA: antibody detection limit dilution at least 1:1,000-2,000. Western Blot: Reacted with the approx 48-kDa Vaspin His tagged protein. Suggested blocking and dilution buffer is PBST with 0.05% Tween 20 with 5% skim milk. Suggested incubation time is 1 hour at room temperature. Recommended for use at dilution 1:500-1,000.
|
|
AAH-PTYR-3-2
|
RayBiotech, Inc.
|
RayBio Human Protein Tyrosine Phosphorylation Antibody Array C3 [2 sample kit]
|
|
|
|
AAH-PTYR-3-4
|
RayBiotech, Inc.
|
RayBio Human Protein Tyrosine Phosphorylation Antibody Array C3 [4 sample kit]
|
|
|
|
AAH-PTYR-4-2
|
RayBiotech, Inc.
|
RayBio Human Protein Tyrosine Phosphorylation Antibody Array C4 [2 sample kit]
|
|
|
|
AAH-PTYR-4-4
|
RayBiotech, Inc.
|
RayBio Human Protein Tyrosine Phosphorylation Antibody Array C4 [4 sample kit]
|
|
|
|
AAH-PTYR-G3-4
|
RayBiotech, Inc.
|
RayBio Human Protein Tyrosine Phosphorylation Antibody Array G3 [4 sample kit]
|
|
|
|
AAH-PTYR-G3-8
|
RayBiotech, Inc.
|
RayBio Human Protein Tyrosine Phosphorylation Antibody Array G3 [8 sample kit]
|
|
|
|
AAH-PTYR-G4-4
|
RayBiotech, Inc.
|
RayBio Human Protein Tyrosine Phosphorylation Antibody Array G4 [4 sample kit]
|
|
|
|
AAH-PTYR-G4-8
|
RayBiotech, Inc.
|
RayBio Human Protein Tyrosine Phosphorylation Antibody Array G4 [8 sample kit]
|
|
|
|